Installation and Wiring / Connecting Motor Feedback Devices / Encoder Connections


Encoder Inputs
Supported Encoder Types Incremental (A,B) with or w/o index pulse; differential or single-ended signals.
Supply Voltage 5.0V +/-5%
Input Voltage Range -0.5 to 5.5V
Available Supply Current 150mA

Terminal Definition
5V Encoder Circuit Supply Voltage
A+ Channel A Positive Differential
A- Channel A Negative Differential
B+ Channel B Positive Differential
B- Channel B Negative Differential
I+ Index Positive Differential
I- Index Negative Differential
GND Encoder Circuit GND
ESHLD Encoder Cable Shield